INUBIT Workbench User Interface

The INUBIT user interface consists of the following areas:

workbench ui
  1. Window title and Toolbar
    In the Window title, the Server ID and the port of the connected Process Engine is displayed. Refer to

  2. Burger Menu
    Refer to Burger Menu.

  3. Main tabs
    The various components of the INUBIT Workbench are displayed in tabs. By clicking on a tab, you can switch backward and forward between the components.

  4. Server/Local tabs
    For creating diagrams and modules you use the staging concept by developing diagrams and modules locally, publishing them for testing on the INUBIT Process Engine and finally deploying them on to the production system. For this staging concept you use the Server and Local tabs.
    Refer to

  5. Working and display area
    Modules and diagrams are created and displayed in this area.

  6. Sidebar

    Access various docking windows, which you can place in the working area and outside the INUBIT Workbench anywhere on your screen.
    The available docking windows are dependent on the displayed tab.
    Refer to

  7. Diagram properties bar
    Displays diagram type, version, and mode of the opened diagram.

Toolbar

Depending on the selected tab, different buttons can be displayed according to the available actions.

Status Information

The status icon workbench user guide 435 0 indicates the status of the Process Engine and provides information on the times and the memory usage when clicking on it.

Save

Click the save icon workbench user guide 435 1 to save settings.

Refresh

The refresh button triggers several actions depending on the selected tab. That’s why it is displayed with different icons:

  • workbench user guide 435 2: There is no automatic refresh. To refresh, you must click the button explicitly.

  • workbench user guide 435 3: The refresh is carried out automatically. You do not have to click the button.

  • workbench user guide 435 4: There is no automatic refresh. To refresh, you do not have to click the button explicitly. You can switch the automatic refresh on or off by clicking on the selection arrow and selecting Autorefresh on or Autorefresh off:

    workbench user guide 435 5
  • workbench user guide 435 6: Refreshing is carried out automatically. You do not have to click the button. You can switch the automatic refresh on or off by clicking on the selection arrow and selecting Autorefresh on or Autorefresh off:

    workbench user guide 435 7

Help (question mark icon)

Opens the online help.

Global search (magnifier icon)

Opens the Global Search dialog, refer to Global Search.

Instant messages (bell icon)

Opens the Instant messages dialog, refer to Instant Messages.
A number in a red ellipse tells you how many new instant messages are available. Clicking on the button opens the messages window and displays the new instant messages.

The display of the signal is deactivated by default.

Burger menu icon

Opens the menu to configure INUBIT, to import and export objects or data, and to open tools, refer to Burger Menu.

Burger Menu

The menu bar contains menus displaying commands. The following commands are displayed permanently, more commands are displayed depending on the currently displayed tab.

Status Information

The status icon workbench user guide 439 0 on the top right, provides the following information.

  • Status of Process Engine

    The status icon indicates the status of the Process Engine. The Process Engine is available when the server icon is displayed green workbench user guide 439 0. If the status icon is displayed in orange workbench user guide 439 1, the maintenance mode is activated for the connected Process Engine (refer to Activating the Maintenance Mode).

When clicking on the status icon, a dialog displays the following information.

  • Workbench time (Local) and Process Engine time (Server)

  • Memory usage/Garbage Collector

    Shows the amount of memory being used by the INUBIT Workbench in relation to the available memory. The Garbage Collector releases memory that is no longer being used. To start the Garbage Collector, click on the memory usage button.

User Menu

  • <Current username> (user group of current user)

    e.g. root (admin)

  • New login

    Opens the login dialog of the INUBIT Workbench.

  • New login as/Leave su-mode

    Refer to Using the su Mode.

  • Switch to additional user group

  • Look and Feel

    For changing the INUBIT Workbench’s theme. You need to restart the INUBIT Workbench to make the change visible.

  • Language in Workbench

    Commands and descriptions in the INUBIT Workbench can optionally be displayed in German or English.

  • Language in diagrams/reports:

    Commands and explanations can be displayed in the “Designer” and “Reporting” tabs in either German or English. To do this, multilingualism must be activated in diagrams and reports and texts must be stored in the additional languages.

  • Change password

    For changing your own password.